Loading...
Table 7: Fan Tray Specicaons
Specicaon JNP10004-FAN2
Corresponding fan tray controller model JNP10004-FTC2
Number of fans per fan tray 6
Number of fans per chassis 12
Fan numbering 0 through 11
Volume ow at 100 percent 948 CFM for both fan trays
Height 12.08 in. (30.68 cm)
Width 6.6 in. (16.8 cm)
Depth 5.5 in. (13.97 cm) without handles, 6.85 in. (17.4 cm) with handles
Weight 9.8 lb (4.45 kg)
The fan tray operates as a single unit. If an individual fan in the tray fails, you must replace the enre fan
tray. However, the fan tray connues to operate indenitely and provides sucient cooling even when a
single fan rotor fails. The fan tray operates indenitely provided that the room temperature is within the
operang range.
If you want to replace an exisng fan tray while the router is running, remove only one fan tray. The
router connues to operate for a limited me with a single operang fan tray without triggering a
thermal alarm.
CAUTION: To avoid triggering a thermal alarm, remove only one fan tray while the
router is operang.