MULTICAL®603
134
KamstrupA/S∙Technicaldescription∙5512‐2029_A1_GB_06.2017
10.8 Powerconsum ptionofmainsconnectedmeter
Thegainedpowerofmetersconnectedto24VACor230VACappearsfromthemarkingonthemeter’sfront.The
markingstatesanaveragemaximumvalueforthemeter’sgainedpower,andoveraperiodoftime,thepowerwill
notexceedthemarking.Forinstanc eshortperiodswithdata
communicationrequireashort‐termincreaseofthe
energyconsumption,whereaslongerperiodswithoutdatacommunicationrequirelessenergy.Thetableshows
examplesofaccumulatedyearlyconsumptionforMULTICAL®603withvarioussupplytypes.Forbatterysupplied
meters,seeparagraph10.3aboutbatterylifetimes.
MULTICAL®603
connectedto
24VACincl.transformer
(66‐99‐403)
MULTICAL®603connected
to
24VACexcl.transformer
MULTICAL®603direct
connectedto230VAC
Gainedpower[W] <1,5W <1W <1W
Apparentpower[VA] <6VA <7VA <11.5VA
Yearlyconsumption
[kWh]
Approx.13kWh Approx.9kWh Approx.9kWh
10.9 Transformer230/24VAC
Thesupplymodulesfor24VACareadjustedforusewitha230/24VACsafetytransformere.g.Kamstruptype66‐99‐
403,whichismountedinacontrolpaneloranotherseparateencapsulation.Regardingpowerconsumptionusinga
safetytransformerinconnectionwith24VACsupplymodules,seeparagraph10.8about
powerconsumptionofmains‐
connectedmeters.
Themaximumcablelengthbetweenthe230/24VACtransformer,e.g.Kamstruptype6699‐403,andMULTICAL®.
Cabletype Maxlength
2x0.75mm
2
50m
2x1.5mm
2
100m
10.10 Supplycablesforsupplym o dule
MULTICAL®603canbesuppliedwithsupplycabletypeH05VV‐F
1
2x0.75mm²tobeusedforboth24VACand230
VAC,ifrequiredbythecustomer.Thesupplycabletothemetermustnotbeprotectedbyafuselargerthantheone
permitted.
Incaseofdoubt,itisrecommendedtoconsultanauthorizedelectricianfor
anevaluationofhowtocarryoutthe
installationconcernedcorrectlywithregardtosafety.
1
H05VV‐FisthetypedesignationofPVC‐isolatedcable,withanominalvoltageof300/500Vandamaxtemperature
of70°C.Duringinstallationpleaseremembertokeepsufficientdistancetohotpartsoftheinstallation.