EasyManua.ls Logo

Kamstrup MULTICAL 603 - Encryption Level >T; Customer Label >VVVV

Kamstrup MULTICAL 603
155 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MULTICAL®603
KamstrupA/S∙Technicaldescription∙55122029
_
A1_GB
_
06.2017
53
3.2.12 Encryptionlevel>T<
MULTICAL®603mustbeorderedwithencrypteddatatransmissionbetweenmoduleandreadingsystem.Datais
encryptedwith128bitAEScountermodeencryption.Datatransmissioncanbeencryptedwitheitheracommonor
anindividualencryptionkey.
Ifyouchooseindividualencryptionkey(Tcode
3)thereadingsystemmustknowtheencryptionkeyoftheindividual
meterinordertoreadthemeter.Theencryptionkeyissenttothecustomerandthen”matched”withtheserial
numberoftheindividualmeterinthereadingsystem.
Ifyouchoosecommonencryptionkey(Tcode2),
thiskeycanbeusedforreadingacustomerspecificnumberof
meters.ThekeyiscreatedbyKamstrupA/S.Acustomercanhaveseveralencryptionkeys,e.g.oneforeachmeter
type.
Note:Thecommonencryptionkeyisonlyofferedtocustomersonrequest.
Theencryptionlevelisc onfigured
aspartofthemeter’sconfigurationnumberviatheTcode.Uponreceiptoforder
theTcodeisbydefaultconfiguredat3‐individualencryptionkey(unlessotherwiseinformedbythecustomer).The
encryptionlevelcanbeconfiguredwhensubmittingtheorder.Theencryptionlevelcannotbechangedafterdelivery.
Encryptionlevel Tcode
Encryptionviacommonkey(customerspecific) 2
Encryptionwithindividualkey 3
EncryptionkeyscanbedownloadedfromKamstrup’scustomerportal“MyKamstrup”atwww.kamstrup.c om.
EncryptionkeysareautomaticallyenteredinUSBMeterReaderandREADy.
3.2.13 Customerlabel>V VVV <
A15x38mmcustomerlabelcanbeprintedonthemeter’sfront.Thecustomerlabeltobeprintedonthemeter’sfront
isdeterminedbytheconfigurationnumberVVVVcode.Thecustomerlabelcanshowutilitylogo,abarcodeorthe
like.Bydefaultthemeter’s
serialnumberiswritteninthecustomerlabelfield.
PleasecontactKamstrupA/Sforinformationaboutpossiblecustomerlabelsaswellasthecreationofanewcustomer
label.
IMPORTANT:Iftheencryptionkeyinthemeterischangedafterdeliveryofthemeter,theencryptiontypeis
changedfromindividualtocommonkeyorviceversa,theTcodeisnotchanged.TheTcodeshowninthe
meter’sdisplayalwaysindicateswithwhichencryptiontypethemeterwas
orderedandnotthemeter’s
t ti t