MULTICAL®603
18
KamstrupA/S∙Technicaldescription∙55122029_A1_GB_06.2017
3.1 Typenumber
MULTICAL®603typenumber
Static
data
603xxxx
Dynamic
data
xxxxxxxx
Writtenonthe
meter’sfront
Canbedisplayed


Type603‐
□ ‐ □ ‐ □□ ‐ □ ‐ □□ ‐ □‐□□ ‐ □□
Calculatortype
  
Pt1002wire t1t2 V1 MBus  A
Pt1004wire t1t2 V1 MBus  B
     
Pt5002wire t1t2 V1 MBus  C
Pt5004wire t1t2 V1 MBus  D
     
Pt5002wire t1t2t3 V1V2
 
E
Pt5002wire t1t2t3 V1V2 Backlitdisplay   F
      
Pt5004wire t1t2 V1(24Vactivepulses)MBus G
Metertype
Heatmeter  MIDmoduleB     1
Heatmeter  MIDmoduleB+D     2
Heat/coolingmeter  MIDmoduleB+D&TS27.02 ϴHC=OFF  3
Heatmeter  Nationalapproval     4
Coolingmeter  TS27.02+BEK1178     5
Heat/coolingmeter  MIDmoduleB+D&TS27.02 ϴHC=ON  6
Volumemeter        7
Energymeter        9
Countrycode
Seeparagraph3.3        XX 
Flowsensorconnectiontype

DeliveredwithoneULTRAFLOW®          1
DeliveredwithtwoidenticalULTRAFLOW®          2
PreparedforoneULTRAFLOW®          7
PreparedfortwoidenticalULTRAFLOW®          8
Preparedforflowsensorwithfastandbouncefreeelectronicpulses         C
Preparedforflowsensorwithslowandbouncefreeelectronicpulses         J
Preparedforflowsensorwithslowpulseswithbounce         L
Preparedforflowsensorwith24Vactivepulses          P
Temperaturesensorset
Notemperaturesensors            00
Pt500temperature senso rpair  
Shortdirectsensorpair 27.5mm 1.5m  11
Shortdirectsensorpair 27.5mm 3.0m 12
Shortdirectsensorpair(3pairs) 27.5mm 1.5m 15 
Shortdirectsensorpair(3pairs) 27.5mm 3.0m 16 
Shortdirectsensorpair 38.0mm 1.5m 21
Shortdirectsensorpair 38.0mm 3.0m 22
Pocketsensorpair ø5.8mm 1.5m 31

Table of Contents

Other manuals for Kamstrup MULTICAL 603

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kamstrup MULTICAL 603 and is the answer not in the manual?

Kamstrup MULTICAL 603 Specifications

General IconGeneral
Flow SensorUltrasonic
Battery LifeUp to 16 years
Power SupplyBattery
Communication OptionsM-Bus, Wireless M-Bus, Modbus, BACnet
DisplayLCD
ApplicationHeating and Cooling
Pressure RatingPN16
ApprovalMID
AccuracyClass 2
Ambient Temperature Range55°C
Housing MaterialBrass