MULTICAL®603
KamstrupA/S∙Technicaldescription∙5512‐2029_A1_GB_06.2017
43
3.2.7 Integrationmode>L<
MULTICAL®603usestime‐basedintegration,whichmeansthataccumulatedvolumeandenergyarecalculatedat
fixed,orvariable,timeintervals.ThetimeintervalisconfigurableviatheL‐codeandindependentofthewaterflow
speed.Pleasebeawarethatchoiceofintegrationmodeincombination
withselectedpowersupplydefinesthemeter’s
batterylifetime.Pleaseseeparagraph10.3rethemeter’sbatterylifetime.
Itispossibletochoosebetweeneightintegrationmodes;fivemodeswherethemeter’sdisplayremainsturnedon,
andthreemodeswherethemeter’sdisplayisturnedoff8min.afterthe
latestregisteredactivationofakey(4min.
afterthelatestregisteredactivationofthekey,themeterreturnstoitsfirstprimaryreading,andafteradditional4
min.,thedisplayturnsoff).Inperiodswiththedisplayswitchedoff,adisplaysegmentflashesatanintervalof30sto
indicatethatthemeterisactive(“heartbeat”indication).
MULTICAL®603canbeorderedwithabacklitdisplay(metertype603‐F).Withtheexceptionofintegrationmode9,it
appliesthatthebackgroundlightingisactivatedbypressingakeyandremainslitfor15s.Ifintegrationmode
9is
selected,thedisplayandthebackgroundlightingbothremainturnedon(mainssupplyisrequired).
L‐code
Integrationmode
Backlight
period
(only603‐F)
Display
on
Display
off
Adaptivemode(2‐64s) 15s. 1 5
Normalmode(32s) 15s. 2 6
Fastmode(8s) 15s. 3 7
Mainsmode(2s) 15s. 4‐
Mainsmode(2s) On 9‐