KamstrupA/S∙Technicaldescription∙55122029_A1_GB_06.2017
3.3 Data
Thecountrycodeisselectedasthelasttwocharactersofthemeter’sstaticpartofthetypenumber.
Staticdata
603xxxx
‐
Dynamicdata
xxxxxxxx
Writtenonthe
meter’sfront
Canbedisplayed

Type603‐ □ XX‐
Inadditiontodefiningthelanguageonthemeterlabelaswellasapprovalandverificationmarks,thecountrycodeis
alsousedtocontroltheconfigurationofanumberofmeterdata.
DuringproductionofMULTICAL®603itisprogrammedwithanumberofmeasuringvalues
inthefieldslistedoverleaf.
Unlesstheorderincludesspecificrequirementsastoconfiguration,MULTICAL®603besuppliedwiththedefault
valuesfromthetable.
Automatic Tobestatedinorder Standard
Serialno.(S/N)
1
(Seeparagraph3.4)
80,000,000‐
Customerno.
DisplayNo.1=8digitsMSD
DisplayNo.2=8digitsLSD
‐
Upto16digits
Customerno.equalto
S/N
Yearlytargetdate1(MM.DD)
‐ MM=112andDD=131
Dependsoncountry
code
Monthlytargetdate1(DD)
‐ DD=131
Yearlytargetdate2(MM.DD)
‐
MM=112andDD=131+
00.00(disabled)
2
Monthlytargetdate2(DD)
‐
DD=131+
00(disabled)
2
Averagingperiodformin./maxof
power(P)andflow(Q)
(Seeparagraph7.5)
‐ 1…1440min. 60min.
AveragingperiodofCP
(Seeparagraph7.2)
‐ 5…30days 7days
hc
Heat/coolingshift
Onlyactiveifmetertype6is
selected
(Seeparagraph7.4)
‐
2…180.00C+250.00C
3
Heat/cooling,metertype
6:
25.00C
Date/time
20YY.MM.DD/
hh.mm.ss
GMT12.0hours
(Canbedefinedathalfhour
intervals)
‐
GMToffset‐
Dependsoncountry
code
PrimaryaddressofMBus,
ModbusandBACnet
4
‐ Address0250
Last23digitsof
customernumber
MBusIDno.
(usedforsecondaryaddress)
‐ ‐ Customerno.
wMBusIDno.‐ Serialnumber

Table of Contents

Other manuals for Kamstrup MULTICAL 603

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kamstrup MULTICAL 603 and is the answer not in the manual?

Kamstrup MULTICAL 603 Specifications

General IconGeneral
Flow SensorUltrasonic
Battery LifeUp to 16 years
Power SupplyBattery
Communication OptionsM-Bus, Wireless M-Bus, Modbus, BACnet
DisplayLCD
ApplicationHeating and Cooling
Pressure RatingPN16
ApprovalMID
AccuracyClass 2
Ambient Temperature Range55°C
Housing MaterialBrass

Related product manuals