MULTICAL®603
46
KamstrupA/S∙Technicaldescription∙55122029_A1_GB_06.2017
3.2.8 Leakagelimits(V1,V2)>M<
MULTICAL®603canbeusedforleakagemonitoringwhentwoflowsensorsareconnectedtoMULTICAL®603onthe
inputsV1andV2. Notethatitisonlypossibletoconnecttwoflowsensorsonthecalculatortypes603E/F.Seethe
typenumberoverview
inparagraph3.1.
TheMcodedefinestheleakag elimit,i.e.thesensitivityoftheleakagemonitoring.Ifaleakageisdetectedinthe
system,aninfocodeindicatingleakageorburstisactivated,dependingonthesizeoftheleakage.Theleakagesearch
isbasedonadifferencein
mass(ΔMass)betweenthecalculatedmassofV1andV2,respectively.Thecalculationof
thismassdifferenceisperformedover24hours,theresponsetimeoftheinfocodeindicatingaleakagethusbeing24
hours.TheburstsearchisbasedonadifferenceinflowofV1andV2,
respectively.Theburstsearchisperformedover
aperiodof120s.Readmoreabouttheseinfocodesintheinfocodeoverviewinparagraph7.7.
ThesensitivityofaleakagecanbeadjustedviatheMcode,whereasthesensitivityofaburstisclearlydefined.This
alsoappears
fromthe tableoftheMcodebelow. Itispossibletodetectleakagesdownto15kg/h throughthe
connectionofthetwoflowsensorsofqp1.5m³/h. Bothinfocodesforleakageandburstcanbedeactivatedviathe
Mcode(M=0).
Leakagelimits (V1,V2)
Mcode
Leakage Burst
Noactiveleaksearch Noactiveburstsearch 0
ΔMass≈> 1.0%ofqp+20%q Δflow>20%ofqp 1
ΔMass≈> 1.0%ofqp+10%q Δflow>20%ofqp 2
ΔMass≈> 0.5%ofqp+20%q Δflow>20%ofqp 3
ΔMass≈> 0.5%ofqp+10%q Δflow>20%ofqp 4
Permanentoperationalmonitoring
Leakagemonitoringcanwithadvantagebeextendedtoincludepermanentoperationalmonitoringasitjustrequires
theinstallationofasetofthreesensorsinsteadofasensorpair.InDenmark,forexample,thepermanent
operationalmonitoringreducesthenumberofrandomsamplestothreemetersper
randomsamplinglot,regardless
ofthesizeofthemeasuringlot.Readmoreintheinstallationguideforpermanentoperationalmonitoring(Kamstrup
guide5511730_DK).Thepurposeoftheseinstructionsistoprovidec aretakers,installersandconsultingengineers
withtheinformationneededaboutKamstrup'sleakagemonitoringsystemandpermanentoperational
monitoring.
0
20
40
60
80
100
120
140
160
180
0 150 300 450 600 750 900 1050 1200 1350 1500
Sensitivity
(flow≈∆Masse)
[l/h≈kg/h]
Averageflowperday(q)
[l/h]
Leakagelimit forqp1,5/h