MULTICAL®603
KamstrupA/S∙Technicaldescription∙5512‐2029_A1_GB_06.2017
105
7.7.1 Informationcodetypesindisplay
InMULTICAL®603eachdigitoftheinfocodeisdedicatedtooneofthemeter’spartelements.Forexample,thesecond
digitfromtheleftinthedisplayisalwaysrelatedtoinformationontemperaturesensort1.Atthesametime,theinfo
code
issectiondividedsothatitfromlefttorightconsistsof:generalinformation,temperatureinformation(t1,t2,
t3),flowinformation(V1,V2)andinformationaboutthepulseinputsAandB(In‐A1/A2andIn‐B1/B2).Foranoverview
ofinfocodes,seethetablebelow.
Displaydigit
1 2 3 4 5 6 7 8
Info t1 t2 t3 V1 V2 In‐A In‐B Description
1
Novoltagesupply
1
2
Lowbatterylevel
9
Externalalarm(e.g.viaKMP)
1
t1Abovemeasuringrangeorswitchedoff
1
t2Abovemeasuringrangeorswitchedoff
1
t3Abovemeasuringrangeorswitchedoff
2
t1Belowmeasuringrangeorshort‐circuited
2
t2Belowmeasuringrangeorshort‐circuited
2
t3Belowmeasuringrangeorshort‐circuited
9 9
t1‐t2Invalidtemperaturedifference
1 V1Communicationerror
1 V2Communicationerror
2 V1Wrongpulsefigure
2 V2Wrongpulsefigure
3
V1Air
3 V2Air
4
V1Wrongflowdirection
4
V2Wrongflowdirection
6
V1Increasedflow(flow1>qs,formorethan1hour)
6 V2Increasedflow(flow2>qs,formorethan1hour)
7 V1/V2Burst,waterloss(flow1>flow2)
7 V1/V2Burst,waterpenetration(flow1<flow2)
8
V1/V2Leakage,waterloss(M1>M2)
8
V1/V2Leakage,waterpenetration(M1<M2)
7 In‐A2Leakageinthesystem
8 In‐A1Leakageinthesystem
9 In‐A1/A2Externalalarm
7 In‐B2Leakageinsystem
2
8 In‐B1Leakageinsystem
2
9 In‐B1/B2Externalalarm
1
Thisinfocodeparameterdoesnotappearfromthecurrentinfocodeasitisonlyactivewhenthemeteriswithout
supply.Theinfocodeissavedintheinfolog,andthusitwillappearfromtheinfologthatthemeterhasbeenwithout
powersupply.
2
InfocodeforleakageatpulseinputBmustbeactivelyselected.
Note: Info codes areconfigurable. Therefore, it is notcertainthat all parameters above are available in a given
MULTICAL®603.Thisdependsontheselectedcountrycode.