MULTICAL®603
KamstrupA/S∙Technicaldescription∙55122029_A1_GB_06.2017
7
1 Generaldescription
MULTICAL®603isanallroundcalculator,suitableasheatmeter,coolingmeterorcombinedheat/coolingmeter
togetherwith1or2flowsensorsand2or3 temperaturesensors.Themeterisintendedforenergymeasurementin
almostalltypesofthermalinstallationswherewaterisusedastheenergy
conveyingmedium.
MULTICAL® 603 can, in addition to heat and cooling measurement, be used for leakage monitoring, permanent
performancemonitoring,aspowerandflowlimiterwithvalvecontrolaswellasforenergymeasurementinbothopen
andclosedsystems.
AccordingtoEN1434andMID,MULTICAL®603canbe
designatedasa“calculator”withseparatetypeapprovaland
verification,anditcanbedeliveredeitherasaseparatecalculatororasacompletemeter,withmountedtemperature
sensorsandflowsensorsaccordingtocustomerrequirements.
The MULTICAL® 603 calculator top can be separated from the connection base without using tools
when the
installationsealsarebroken.Thisprovidesfreeaccesstotheinstallationoftheflowsensor,temperaturesensors,
powersupply/batteryandcommunicationmodules.
Thecalculatortopisfactorysealedandmayonly beopenedbyauthorisedmeterlaboratories.Ifthefactorysealis
broken,thefactoryguaranteenolonger
applies.
MULTICAL®603has2flowsensorinputsthatcanbeusedforbothelectronicandmechanicalflowsensors.Thepulse
figurecabbeprogrammedfrom0.001to300pulses/liter,andthecalculatorcanbeprogrammed toallnominalflow
sensorsizesfrom0.6to15,000m
3
/h.Thecalculatorcanbedeliveredwithbothgalvanicallyconnectedandseparated
flowsensorinputs.
The temperaturemeasurements in inlet andoutlet areperformed withaccurately paired Pt500or Pt100 sensor
accordingtoEN60751andEN1434.MULTICAL®603normallycomeswithaPt500sensorpair,e.g.shortdirect
sensors
accordingtoEN14342orø5.8mmpocketsensors,whichfitKamstrupsensorpocketsinstainlesssteel.MULTICAL®
603canalsobedeliveredwith4wiretemperaturesensorinputsthatareespeciallysuitableforinstallationswithlong
temperaturesensorcables.
Accumulatedheatenergyand/orcoolingenergycanbe
displayedinkWh,MWh,GJorGcal,allwithsevenoreight
significantdigitsplusmeasuringunit.Thedisplayhasbeenspeciallydesignedwithaviewtoobtaininglonglifetime
andsharpcontrastinawidetemperaturerange.Furthermore,MULTICAL®603canbedeliveredinavariantwith
backlitdisplay(type
603F).
Otherreadingoptionsare:accumulatedwaterconsumption,operatinghourcounter,errorhourcounter,current
temperaturemeasurements,currentflowandpowerreadings.Furthermore,MULTICAL®603canbeconfiguredto
displaymonthlyandyearlyloggings,targetdatedata,max/min.flow,max/min.power,informationcode,currentdate
aswellasuser
definedtariffing.
MULTICAL®603ispoweredbyaninternalDcelllithiumbatterywithalifespanupto16yearsora2xAlithiumpacket
withalifespanofupto9years.Alternatively,themetercanbemainssupplied,eitherby24VACor230VAC.
Inadditiontothe
energymeter’sowndata,MULTICAL®603candisplaytheaccumulatedconsumptionsoftwoextra
watermeters,e.g. coldand hotwatermeters, whichsupply apulsesignalto MULTICAL®603 viareedswitch or
electronicoutput.Thecontactsignalsfromtheextrawatermetersareconnectedviathecommunicationmodules.
Amultipleplugplacedbehindthesealisusedinconnectionwithcalibrationandadjustmentduringverificationaswell
asinconnectionwithcommunicationmodules.MULTICAL®603isavailablewith1or2communicationmodulesfor
WirelessMBus,MBusandRS232.Themodulesareavailablewitheitherpulseinputs
orpulseoutputs.Furthermore,
themetercanbedeliveredwithintegratedMBus,independentofthemodules.
Indesign ingMULTICAL®603,greatimportancehasbeenattachedtoflexibilitythroughprogrammablefunctionsand
pluginmodules(see paragraphs3.2and11) inordertosecureoptimumusein awide range
ofapplications.In
addition, the construction makes it possible to update previously installed MULTICAL® 603 via the PCprogram
METERTOOLHCW.

Table of Contents

Other manuals for Kamstrup MULTICAL 603

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kamstrup MULTICAL 603 and is the answer not in the manual?

Kamstrup MULTICAL 603 Specifications

General IconGeneral
Flow SensorUltrasonic
Battery LifeUp to 16 years
Power SupplyBattery
Communication OptionsM-Bus, Wireless M-Bus, Modbus, BACnet
DisplayLCD
ApplicationHeating and Cooling
Pressure RatingPN16
ApprovalMID
AccuracyClass 2
Ambient Temperature Range55°C
Housing MaterialBrass