MULTICAL®603
KamstrupA/S∙Technicaldescription∙5512‐2029_A1_GB_06.2017
21
3.2 Configurationnumber
ThesoftwareconfigurationofMULTICAL®603isdefinedonthebasisoftheconfigurationnumber.Belowyouseean
overviewofthemeter’sconfigurationnumber.Eachpartoftheconfigurationnumberisdescribedinmoredetailin
thefollowingparagraphs.
A‐B‐CCC‐DDD‐EE ‐ FF ‐ GG ‐ L ‐ M ‐ N ‐ PP ‐ RR‐ T‐VVVV
Flowsensorposition
Inlet 3
Outlet 4
Measuringunit
GJ 2
kWh
1
3
MWh 4
Gcal 5
AutoDetectCCCcodes(UFx4)
Normalresolution(7digits) 807
Highresolution(8digits) 818
StaticCCCcodes
Reedswitch(7digits) 0xx
Electronic,fastpulse(7digits) 1xx
Electronic,fastpulse(8digits) 2xx
Kamstrup,UFX4(7digits) 4xx
Kamstrup,UFX4(8digits) 5xx
Electronic,slowpulse(7digits) 9xx
Display
Heatmeter(standard)
210
Heat/coolingmeter(standard) 310
Coolingmeter 510
Tariffs
Noactivetariff 00
Powertariff 11
Flowtariff 12
t1‐t2tariff 13
Inlettariff 14
Outlettariff 15
Timecontrolledtariff 19
Heat/coolingvolumetariff 20
PQ‐tariff 21
PulseinputsAandB
10m
3
/h,10l/imp,pre‐counter1(standard) 24 24
Integrationmode
1
Adaptivemode(2‐64s) Displayon 1
Normalmode(32s) Displayon 2
Fastmode(8s) Displayon 3
Mainsmode(2s) Displayon 4
Adaptivemode(2‐64s) Displayoff 5
Normalmode(32s) Displayoff 6
Fastmode(8s) Displayoff 7
Mainsmode(2s) Display&backlighton 9
Leakagelimits(V1/V2)
OFF 0
1.0%ofqp+20%ofq 1
1.0%ofqp+10%ofq 2
0.5%ofqp+20%ofq 3
0.5%ofqp+10%ofq 4
Leakagelimit,coldwater(In‐A/In‐B)
OFF 0
30min.withoutpulses 1
Onehourwithoutpulses 2
Twohourswithoutpulses 3
PulseoutputsCandD
Out‐C:V1/1,Out‐D:V2/1 3.9ms 80
Out‐C:V1/1 3.9ms 82
Out‐C:V1/4 22ms 83
E1andV1orE3andV1 10ms 94
E1andV1orE3andV1 32ms 95
E1andV1orE3andV1 100ms(0.1s) 96
Controlledoutputbasedondatacommands 99