MULTICAL®603
28
KamstrupA/S∙Technicaldescription∙5512‐2029_A1_GB_06.2017
3.2.4 Displaycode>DDD<
MULTICAL®603has4displayloops;USER,TECH,SETUPandTEST.TheTECHloopcontainsalldisplayreadings,with
theexceptionofloggedvaluesandthedifferentialregisters,andthisloopisnotconfigurable.USERloop,however,is
configurableandcanbeadaptedtocustomerrequirementsbymeansoftheDDDcode(displaycode).Asaminimum,
theUSERloopcomprisesthemeter’slegalreadings.
Themeter’slegalreadings,e.g.energyandvolumereading,arebasicallydisplayedas7‐digitvalues.Thedisplay
readingscanbeconfiguredto8
‐digitvaluesviatheDDDcode.PleasecontactKamstrupforfurtherdetails.
Thefirstdigitsofthethree‐digitDDD‐codedefinethemetertypecomprisedbytheDDD‐codeinquestion.Thetable
showsexamplesofanumberofDDD‐codeswithineachmetertype.Inthetable,”1”indicates
thefirstprimaryreading,
wherease.g.”1A”isthefirstsecondaryreading.Thedisplayautomaticallyreturnstoreading“1”after4minutes.
ContactKamstrupA/Sforinformationaboutavailabledisplaycodes.
Displayref.
Primaryreading
Displayref.
Secondaryreading
Heatmeter
DDD=110
Heatmeter
DDD=210
Heat/coolingmeter
DDD=310
Heatmeter
DDD=410
Coolingmeter
DDD=510
Heat/coolingmeter
DDD=610
Volumemeter
DDD=710
1.0 Heatenergy(E1) 1 1 1 1 1
1.1 Dateofyearlylogger
1A 1A 1A 1A1A
1.2 Dataofyearlylogger
1
1.3 Dateofmonthlylogger
1B 1B 1B 1B1B
1.4 Dataofmonthlylogger
1
1.5 E1High‐resolution
2.0 Coolingenergy(E3) 2 1 2
2.1 Dateofyearlylogger
2A1A 2A
2.2 Dataofyearlylogger
1
2.3 Dateofmonthlylogger
2B1B 2B
2.4 Dataofmonthlylogger
1
2.5 E3High‐resolution
3.0 EnergyE2
3.1 EnergyE4
3.2 EnergyE5
3.3 EnergyE6
3.4 EnergyE7
4.0 VolumeV1 2 2 3 2 2 3 1
4.1 MassV1
4.2 PressureP1
4.3 Dateofyearlylogger
2A 2A 3A 2A 2A 3A 1A
4.4 Dataofyearlylogger
1
4.5 Dateofmonthlylogger
2B 2B 3B 2B 2B 3B 1B
4.6 Dataofmonthlylogger
1
4.7 V1High‐resolution
5.0 VolumeV2
5.1 MassV2
5.2 PressureP2
5.3 Dateofyearlylogger
5.4 Dataofyearlylogger
1
5.5 Dateofmonthlylogger
5.6 Dataofmonthlylogger
1