MULTICAL®603
KamstrupA/S∙Technicaldescription∙5512‐2029_A1_GB_06.2017
23
3.2.3 Flowsensorcoding>CCC<
TheCCC‐codeoptimisesthedisplayresolutionfortheselectedflowsensorsize,andatthesametimeth etypeapproval
regulations as to minimumresolution and maximum register overflow are observed. Below, thepossible display
resolutionswithMULTICAL®603accordingtothetyp eapprovalrules
areshown.
Numberofdecimalsindisplay
Energy Volume/
Mass
Flow/
Power
qp
[m
3
/h]
7/8digits kWh
1
MWh
Gcal
GJ m
3
tons
l/h m
3
/h kW MW
0.6≤1.5 7 1 4 3 3 0 ‐ 1 ‐
0.6≤15
7 0 3 2 2
0 ‐ 1
‐
8 1 4 3 3 ‐
4≤150
7
‐ 2 1 1
‐ 2 0
‐
8 0 3 2 2 ‐
40≤1500
7
‐ 1 0 0
‐ 1 ‐ 2
8 ‐ 2 1 1
400≤15000
7
‐ ‐ ‐ ‐
‐
‐
‐
‐
8 ‐ 1 0 0 0 1
TheCCCcodesforMULTICAL®603 aregroupedaccordingtothetypeofconnectedflowsensor.Ninegroupshave
beencreated,whicharealltiedtoaconnectiontype.The connectiontypeisselectedaspartofthemeter’stype
number.
CCC Flowsensortype Pulse
frequency
Bounce
dampin
g
Pulses
+Data
Auto
Detect
7/8
digits
Connectiontype Pulsetime
Direct Opto ON(LO) OFF(HI)
0XX
Mechanical meters delivering
slowpulseswithbounce
<1Hz Yes P
No
7/8 L‐>300ms >10ms
1XX
Electronicmeterswithquickand
bounce‐freepulses
<128Hz
No
P
7 C‐7‐8
1
P
>1ms >4ms
2XX 8 C
4XX
Electronicmeterswithquickand
bounce‐free pulses as well as
data for info codes for
ULTRAFLOW®X4
P+D
7
1‐2‐7‐8
1
‐
5XX 8
8XX
Electronicmeterswithquickand
bounce‐free pulses as well as
data for info codes for
ULTRAFLOW® X4 and self‐
configuration
Yes
7/8
9XX
Electronicmeterswithslowand
bounce‐freepulses
<8
Hz
P No J >30ms >100ms
1