EasyManua.ls Logo

Kamstrup MULTICAL 603 - Page 24

Kamstrup MULTICAL 603
155 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MULTICAL®603
24
KamstrupA/S∙Technicaldescription∙55122029_A1_GB_06.2017
Inthefollowingfiveparagraphs,theCCCcodesaredescribed.
3.2.3.1 ULTRAFLOW®X4
3.2.3.2 Mechanicalflowsensors,reedswitch
3.2.3.3 Electronicflowsensors,slowpulses
3.2.3.4 Electronicflowsensors,fastpulses
3.2.3.5 ULTRAFLOW®II,65SRTandX4
3.2.3.1 ULTRAFLOW®X4
AutoDetectenablestheexchange ofULTRAFLOW®X4onMULTICAL®603withoutchangingtheCCCcode.MULTICAL®
603canautomaticallyadaptitsCCCcodetomatchtheconnectedULTRAFLOW®X4viathefunctionAutoDetect.Auto
DetectisactivewithCCCcode8xx.
Auto Detect functions in such a way that
MULTICAL® 603 during startup automatically retrieves the correct
informationaboutpulsefigureandqpfromtheconnectedULTRAFLOW®X4flowsensors.MULTICAL®603adaptsits
configurationtothevaluesreceivedfromULTRAFLOW®X4.AutoDetectisinitiatedwhenthecalculatortopandbase
areseparatedandreassembled.Readmore
abouttheconnectionofULTRAFLOW®andAutoDetectinparagraph8.1.
MULTICAL®603canbedeliveredwithAutoDetectifthisisdeliveredwithaCCCcode8xx,butcanalsobedelivered
withastaticCCCcode4xx(7digits)or5xx(8digits).Afterthedelivery,itispossible
tochangetheCCCcodeandselect
AutoDetectandviceversa.
Normalresolution
7digits
Highresolution
7digits
Highresolution
8digits
 Numberofdecimalsindisplay
CCC qp Imp./L 7/8
digits
kWh
1)
MWh
Gcal
GJ m
3
tons
l/h m
3
/h kW MW Connection
type
807 0,6…1000 300…0.15 7
AutoDetect,CCCcodes:
416419498451437478420479458470480447481491492493
1278
818 0,6…1000 300…0.15 8
AutoDetect,CCCcodes:
584507598536538583585579586587588589581591592593
1278
1
WhenselectingkWh,themeterautomaticallychangestoMWhwhentheCCCcodeisselectedforlargermeters.
