MULTICAL®603
146
KamstrupA/S∙Technicaldescription∙5512‐2029
A1_GB
06.2017
11.6 Supplyofmodules
Moduleslot2
Moduleslot1
00 10 20 30 50 11 21 11 22 40 41 66 67 60
00 Nomodule
10 Data+
2pulseinputs(In‐A,In‐B)
20 M‐Bus,configurable+
2pulseinputs(In‐A,In‐B)
30 WirelessM‐Bus,EU,
configurable,868MHz+
2pulseinputs(In‐A,In‐B)
50 KamstrupRadio(low‐power)+
2pulseinputs(In‐A,In‐B)
11 Data+
2pulseoutputs(Out‐C,Out‐D)
21 M‐Bus,configurable+
2pulseoutputs(Out‐C,Out‐D)
11 Data+2pulseoutputs(Out‐C,
Out‐D),Usedpulsetransmitter
(V1+V2)
22 M‐Bus,configurable+
w/ThermalDisconnect
40 Analogoutputmodule
2x0/4…20mA
41 Analoginputmodule
2x0/4…20mA
66 BACnetMS/TP(RS‐485)+
2pulseinputs(In‐A,In‐B)
67 ModbusRTU(RS‐485)+
2pulseinputs(In‐A,In‐B)
60 LonWorks+
2pulseinputs(In‐A,In‐B)
Batterysupply
Mainssupply
High‐powerSMPS
Overview of battery lifeti mes, estimated lifetime [years], of differently configured MULTICAL® 603 is shown in
paragraph10.3.