MULTICAL®603
84
KamstrupA/S∙Technicaldescription∙55122029
_
A1_GB
_
06.2017
Normalresolution
Resolution
level
MWh
Gcal
kWh GJ m
3
tons
3 0.0001 0.1 0.001 0.001
2 0.001 1 0.01 0.01
1 0.01‐ 0.1 0.1
0 0.1‐ 1 1
Table1,Normalresolution
Flowsensorsize Highresolution
qp≤1.5 0.001kWh 0.01litre
1.5<qp≤15 0.01kWh 0.1litre
15<qp≤150 0.1kWh 1litre
150<qp≤1500 1kWh 0.01m
3
1500<qp≤15000 0.01MWh 0.1m
3
Table2,Highresolution
Energy Volume
Normalresolution

Highresolution

Table3
,
Examplesofnormalandhighresolution
WhilethemeterisinTESTmode,allintegrationsarecarriedoutatanintervalof2seconds,irrespectiveofthechosen
Lcode.
The above high resolution registers can also be seen in the TECH loop, see paragraph 6.2. However, here the
integrationintervalwillfollowthemeter’susualinterval,
definedbytheLcode.
WhilethemeterisinTESTmode,highresolutionpu lsescanbegeneratedfortestpurposesviaPulseinterface(see
paragraph13).