:SOURce EXPRession<1-8>|NONE Sets the on-couple signal source to an expression.
:DELay
:FALL <value> Sets the output turn-off sequence delay.
:RISE <value> Sets the output turn-on sequence delay.
:INHibit
:MODE LATChing|LIVE|OFF Sets the operating mode of the remote inhibit digital pin.
:PON
:STATe RST|RCL0 Sets the output power-on state.
:PROTection
:CLEar Resets the latched protection.
:MODE Sets the turn-off behavior for all protection conditions.
:TEMPerature
:MARGin? Returns the margin remaining before the over-tem-
perature trips.
:USER
[:STATe] 0|OFF|1|ON Enables or disables the user-defined protection.
:SOURce EXPRession<1-8>|NONE Sets the user-defined protection source to an expression.
:WDOG
[:STATe] 0|OFF|1|ON Enables or disables the I/O watchdog timer.
:DELay <value> Sets the watchdog delay time.
:RELay
:LOCK
[:STATe] 0|OFF|1|ON Enables or disables the locked-closed state of the output
relays.
:POLarity NORMal|REVerse Sets the polarity of the output relays.
:ENABle 0|OFF|1|ON Enables or disables the polarity reversal function.
SENSe Subsystem
SENSe
:AHOur
:RESet Resets the amp-hour or watt-hour measurement to zero.
:BBR
:PERiod <value> Sets the recording period of the black box recorder in seconds.
:CURRent
[:DC]
:RANGe
[:UPPer] <value> Selects a DC current measurement range.
:AUTO 0|OFF|1|ON Enables or disables seamless measurement auto ranging.
:ELOG
:CURRent
[:DC]
:RANge
[:UPPer] <value> Selects the Elog current measurement range.
:AUTO 0|OFF|1|ON Enables or disables Elog seamless measurement autoranging.
1 Quick Reference
30 Keysight N6900/N7900 Series Operating and Service Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies N6900 Series and is the answer not in the manual?

Keysight Technologies N6900 Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelN6900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals