:FUNCtion
:CURRent 0|OFF|1|ON Enables/disables current data logging.
:MINMax 0|OFF|1|ON Enables/disables min/max current data logging.
:VOLTage 0|OFF|1|ON Enables/disables voltage data logging.
:MINMax 0|OFF|1|ON Enables/disables min/max voltage data logging.
:PERiod <value> Sets the integration time of an Elog measurement.
:FAULt
:STATe 0|OFF|1|ON Enables or disables remote sense fault detection.
:SWEep
:NPLCycles <value> Sets the measurement time in number of power line cycles.
:OFFSet
:POINts <value> Defines the offset in a data sweep for triggered meas-
urements.
:POINts <value> Defines the number of points in a measurement.
:TINTerval <value> Defines the time period between measurement samples.
:THReshold<1|2|3|4>
:AHOur
[:LEVel] <value> Sets the amp-hour level for comparator 1,2,3, or 4.
:CURRent
[:LEVel] <value> Sets the current level for comparator 1,2,3, or 4.
:FUNCtion
VOLT|CURR|POW|AHO|WHO
Sets the sensing function for comparator 1,2,3, or 4.
:OPERation GT|LT Sets the comparison type for comparator 1,2,3, or 4.
:POWer
[:LEVel] <value> Sets the power level for comparator 1,2,3, or 4.
:VOLTage
[:LEVel] <value> Sets the voltage level for comparator 1,2,3, or 4.
:WHOur
[:LEVel] <value> Sets the watt-hour level for comparator 1,2,3, or 4.
:WHOur
:RESet Resets the accumulated watt-hour measurement.
:WINDow
[:TYPE] HANNing|RECTangular Selects the measurement window.
[SOURce:]ARB Subsystem
[SOURce:]
ARB
:COUNt <value>|INFinity Specifies the number of times the Arb repeats.
:CURRent
:CDWell
[:LEVel] <value>{,<value>}|<Block> Specifies the level of each point in the Arb.
:DWELl <value> Specifies the dwell time of each point in the Arb.
:POINts? Returns the number of points in the Arb.
:FUNCtion
Keysight N6900/N7900 Series Operating and Service Guide 31
1 Quick Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keysight Technologies N6900 Series and is the answer not in the manual?

Keysight Technologies N6900 Series Specifications

General IconGeneral
BrandKeysight Technologies
ModelN6900 Series
CategoryPower Supply
LanguageEnglish

Related product manuals