[SOURce:]Resistance Subsystem
[:SOURce]
:RESistance
[:LEVel]
[:IMMediate]
[:AMPLitude] <value> Sets the output resistance level.
:STATe 0|OFF|1|ON Enables or disables output resistance programming.
[SOURce:]STEP Command
[SOURce:]
:STEP
:TOUTput0|OFF|1|ON Specifies whether a trigger out is generated when a transient step occurs.
[SOURce:]VOLTage Subsystem
[SOURce:]
VOLTage
[:LEVel]
[:IMMediate]
[:AMPLitude] <value> Sets the output voltage when in voltage priority mode.
:TRIGgered
[:AMPLitude] <value> Sets the triggered output voltage.
:BWIDth LOW|HIGH1 Sets the voltage bandwidth.(for backward compatibility)
:LEVel 0|1, <value> Sets the programming pole frequency.
:RANGe 0|1 Sets the voltage bandwidth.
:LIMit
[:POSitive]
[:IMMediate]
[:AMPLitude] <value> Sets the voltage limit when in current priority mode.
:MODE FIXed|STEP|LIST|ARB Sets the transient mode.
:PROTection
[:LEVel] <value> Sets the over-voltage protection level.
:RESistance
[:LEVel]
[:IMMediate]
[:AMPLitude] <value> Sets the output resistance when in voltage priority mode.
:STATe 0|OFF|1|ON Enables or disables resistance programming in voltage pri-
ority mode.
:SLEW
[:IMMediate] <value>|INFinity Sets the voltage slew rate.
:MAXimum 0|OFF|1|ON Enables or disables the maximum slew rate override.
1 Quick Reference