9 Programming the Instrument
9.4 Status Register System & STATus Subsystem
Min 0
Max 32767
Status Bits/OPC
dependencies
Sequential command
Questionable Integrity Signal Positive Transition
Determines which bits in the "Questionable Integrity Signal Condition" on page 1147
register will set the corresponding bit in the "Questionable Integrity Signal Event
Query" on page 1148 register when the condition register bit has a positive
transition (0 to 1).
The variable <integer> is the sum of the decimal values of the bits that you want to
enable.
Remote
Command
:STATus:QUEStionable:INTegrity:SIGNal:PTRansition <integer>
:STATus:QUEStionable:INTegrity:SIGNal:PTRansition?
Example
:STAT:QUES:INT:SIGN:PTR 4
Burst not found being set will be reported to the Integrity Summary of the Status Questionable register
Preset 32767
Min 0
Max 32767
Status Bits/OPC
dependencies
Sequential command
9.4.6.15 Questionable Integrity Output Register
Monitors conditions that occur in connection status currently limited to ODI
streaming . It summarizes them in bit 2 of the "Questionable Integrity Register" on
page 1142.
1149 IQ Analyzer Mode User's &Programmer's Reference