Use standard power cables, encoder cables and control
cables to ensure that the cables are correctly wired and
not loose or damaged.
◆
Initialize the control parameters—store the control
parameters and restart and try to run
◆
Twist the motor bearing by hand to check whether the
motor is abnormal, and try to reinstall the motor oil
seal
◆
Adjust the drive control loop parameters according to
chapter 7.1
◆
Use shielded twisted pair cables for pulse lines. When
the cables are long, the diameter of the control lines
should be appropriately increased. The pulse line
should be kept away from the power line as far as
possible, and the drive and the motor should be well
grounded.
◆
Restore factory gear ratio operation.
◆
Restore the machine to the original under the
conditions allowed by the process, and search for the
origin before the accumulated error exceeds the
allowable.
◆
Check whether the coupling equipment is firmly
installed, the pulleys or gears are well engaged,
whether the load inertia is too large, try to reduce the
load or replace the motor with higher power, etc.