Kinco FD5 使用手
第四章 数字面板操作
49
EA00
Save parameters
Write “1” to save control and motor parameters.
Write “2” to save control and motor parameters and reboot the servo.
Write “3” to reboot the servo.
Write “10” to initialize the control parameters.
After saving the parameters, the drive sets the control loop parameters
according to the load type and application.
-
When EA02 is set to 0, 1 or 2, the default input and output functions are as follows:
Table 4-3 Default IO configuration related to EA02
Pulse Train
Control via RS232
CW/CCW
P/D(default)
A/B
EA02
0
1
2
8
DIN1
Enable
Enable
Enable
DIN2
Reset errors
Reset errors
Reset errors
DIN3
Start homing
Start homing
Start homing
DIN4
P limit+
P limit+
P limit+
P limit+
DIN5
P limit-
P limit-
P limit-
P limit-
DIN6
DIN7
Home signal
Home signal
Home signal
Home signal
OUT1
Ready
Ready
Ready
Ready
OUT2
Motor brake
Motor brake
Motor brake
Motor brake
OUT3
Pos reached
Pos reached
Pos reached
Pos reached
OUT4
Zero Speed
Zero Speed
Zero Speed
Zero Speed
OUT5
Error
Error
Error
Error
Work model-4
Work model0
Attention
Changing the EA02 may cause the IO function to change, so the actual IO input may
unexpectedly activate the corresponding function of the drive. Therefore, when
setting the EASY menu, it is recommended to disconnect the wiring of the X4
interface, or disconnect the power supply of the digital input port