Kinco FD5 使用手
第六章 工作模式介绍
90
Table
6-16
Input port function of PosTable mode
Name
Description
PosTable Cond0
If Cond0 ON, Condition0 = PosTable Cond0 (refer to introduction concerning Cond0 ON)
PosTable Cond1
If Cond1 ON, Condition1 = PosTable Cond1 (refer to introduction concerning Cond1 ON)
Start PosTable
Start position flow
PosTable Idx0
Entry index of position flow, bit0: PosTable Idx0; bit1: PosTable Idx1; bit2: PosTable Idx2. A
bit which is not configured to DIN means 0.
PosTable Idx1
PosTable Idx2
Abort PosTable
Abort position flow
Table
6-17
OUT functions of the position flow mode
Name
Description
PosTable Active
Position flow mode running
In the PC software, click menu item Controller->Control Modes->Position flow Mode in order to
enter position flow parameter settings.