8.3 Wiring
The installation procedure is described as an example. A different procedure may be
appropriate or necessary, depending on the application of the equipments.
We provide further know-how through training courses (on request).
DANGER
High voltage up to 900V!
There is a danger of electrical arcing with damage to contacts and
serious personal injury.
l
Only install and wire up the equipment when it is not live, i.e. when
neither the electrical supply nor the 24 V auxiliary voltage nor the
supply voltages of any other connected equipment is switched on.
l
Make sure that the cabinet is safely disconnected (for instance, with a
lock-out and warning signs).
The ground symbol X, which you will find in all the wiring diagrams, indicates that you
must take care to provide an electrically conductive connection with the largest feasible
surface area between the unit indicated and the mounting plate in the control cabinet.
This connection is for the effective grounding of HF interference, and must not be con-
fused with the PE-symbol W (PE = protective earth, safety measure as per IEC60204).
Use the following connection diagrams :
Safety Function STO : page 42
Overview : page 57
Mains power : page 59
Motor : page 64
Feedback : page 65ff
Electronic Gearing / Master Slave
Master-Slave : page 87
Pulse-Direction : page 88
Encoder Emulation
ROD (A quad B) : page 90
SSI : page 91
Digital and analog inputs and outputs : page 92ff
RS232 / PC : page 95
CAN Interface : page 96
Expansion cards
I/O-14/08 : page 118
PROFIBUS : page 119
sercos
®
II : page 121
DeviceNet : page 122
SynqNet : page 126
FB-2to1 : page 127
2CAN : page 130
Options
EtherCAT : page 131
FAN : page 132
S300 Instructions Manual 51
Kollmorgen 02/2017 Electrical installation