4.2.2 Safety Conformance (STO) according to Machine Directive
The S300 servo amplifier offers a single channel STO function (Safe Torque Off) that can
be used as a functional safe restart lock.
The safetys concept is certified. The safety circuit concept for realizing the safety function
"Safe Torque Off" in the servo amplifiers S300 is suited for SIL CL 2 according to IEC
62061 and PLd according to ISO 13849-1.
The subsystems (servo amplifiers) are totally described for safety technics with the
characteristic data SIL CL, PFH
D
and T
M
.
Device Operation mode EN 13849-1 EN 62061 PFH
D
[1/h] T
M
[Year]
STO-Enable single channel PLd SIL CL 2 1,50E-07 20
4.3 EAC Conformance
EAC is the abbreviation for Eurasian Conformity. The mark is used in the states of the
Eurasian Customs Union (Russia, Belarus, Kazakhstan) similar to the European CE
mark.
Kollmorgen declares, that the S300 has passed all required conformity procedures in a
member state of the Eurasian Customs Union, and that the S300 meets all technical
requirements requested in the member states of the Eurasian Customs Union: