Parameters
Operating manual for INVEOR α | DOC01539818 - 0004 | 2017-01 | V2.0 EN 63
Fixed frequency
This operating mode controls the drive controller with up to 3 fixed target values.
These are selected under parameter 2.050, where you can select how many fixed frequencies are
to be used.
Parameter Name Selection
options
Function Number of
digital inputs
needed
2.050
Fixed frequency/
mode
Foil keypad (option)
Foil keypad (option)
0
1
3
4
1 fixed frequency
3 fixed frequencies
2 fixed frequencies
2 fixed frequencies
1
2
-
-
Depending on the number of fixed frequencies required, up to 3 digital inputs are permanently
assigned in the table.
Parameter Name Presetting DI2 DI1
1.020
Min. frequency 0 Hz 0 0
2.051
Fixed
frequency 1
10 Hz 0 1
2.052
Fixed
frequency 2
20 Hz 1 0
2.053
Fixed
frequency 3
30 Hz 1 1
Tab. 2: Logic table for fixed frequencies