Parameters
Operating manual for INVEOR α | DOC01539818 - 0004 | 2017-01 | V2.0 EN 93
5.075
5.4 Gearbox factor
Unit:
Relationship
to parameter:
33.034
Parameter
manual:
P. xy
Transfer status:
2
min.:
0 Own value
(to be entered!)
max.: 1000
def.: 1
A gearbox factor can be set here.
The mechanical speed display can be adjusted using the gearbox factor.
5.4.1 Blocking detection
5.080 Blocking detection Unit: integer
Relationship
to parameter:
5.081
Parameter
manual:
P. xy
Transfer status:
2
min.:
0 Own value
(to be entered!)
max.: 1
def.: 0
This parameter can be used to activate stall detection.
0 = disable
1 = enable
5.081 Blocking time Unit: s
Relationship
to parameter:
5.080
Parameter
manual:
P. xy
Transfer status:
2
min.:
0 Own value
(to be entered!)
max.: 50
def.: 2
Indicates the time after which a blockage is detected.