EasyManua.ls Logo

Kostal INVEOR Drive Controller - Safety Instructions for Working with Parameters; General Information on Parameters; Explanation of Operating Modes

Kostal INVEOR Drive Controller
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
60 Operating manual for INVEOR α | DOC01539818 - 0004 | 2017-01 | V2.0 EN
This chapter contains the following:
an introduction to the parameters
an overview of the most important commissioning and operation parameters
5.1 Safety instructions for working with parameters
DANGER!
Risk of death due to restarting motors!
Death or serious injury!
Non-observance may result in death, serious injury or damage.
Certain parameter settings and changing parameter settings during operation
may result in the INVEOR α drive controller restarting automatically after the
supply voltage has failed, or in undesirable changes in the operating behaviour.
INFORMATION
If parameters are changed while the device is in operation, it may take a few seconds for the
effect to become noticeable.
5.2 General information on parameters
5.2.1 Explanation of operating modes
The operating mode is the instance in which the target value is generated.
In the case of frequency setting mode, this is a simple conversion of the raw input target value into
a rotation speed target value. In the case of PID process control, the target value and actual value
are compared and the system then regulates to a specific process variable.

Table of Contents