Note that the total audio delay will be the sum of the Auto Track delay, and any delay
specified in the Fixed Delay option detailed earlier in this chapter.
The Autotrack indicator on the front panel of the unit will be lit when this option is
enabled.
Master Mute
When enabled, this option mutes all of the audio output channels.
Valid Settings: Off, On
Default Setting: Off
Audio Bypass
Toggles between bypassing and processing the analog and AES/EBU audio inputs.
Valid Settings: Process, Bypass
Default Setting: Process
Process mode is the normal mode of operation. In Bypass mode, no processing is
applied to the analog and AES/EBU audio inputs; they are bypassed directly to the
outputs.
The analog and AES/EBU audio inputs are also bypassed when the power to the unit
is off.
This setting is overridden by the master Bypass key on the front panel of the
unit. If the front panel is used to select the master Bypass mode, the analog and
AES/EBU audio inputs will be bypassed regardless of the setting of this option.
AES Data Grade
Specifies the AES/EBU grade as either professional or consumer, which affects how
the channel status bits in the AES data stream are handled.
Valid Settings: Pro, Consumer
Default Setting: Pro
AES Elec. Levels
Specifies the AES/EBU electrical levels as either AES or S/PDIF.
Valid Settings: AES, SPDIF
Default Setting: AES
Related Setting: AES Data Grade
The AES Data Grade option may need to be changed in conjunction with this setting
to properly process certain AES data streams.
AES Source
Specifies whether the BNC or XLR connections on the optional 774-470 AES/EBU
Audio Breakout Cable are used for AES/EBU input.
Valid Settings: BNC, XLR
Default Setting: BNC
52
DPS-475/575 Service Manual