EasyManua.ls Logo

Leitch DPS-475 - Chapter 10: Menus: Timing Setup; Genlock; Subcarrier Phase; Horizontal

Default Icon
248 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 10:
Menus: Timing Setup
CHAPTER 10: MENUS: TIMING SETUP
The Timing Setup Menu is used to time the unit to an external genlock source. Note
that changes to these options will not be available if the Genlock Changes setting
in the System Config menu is disabled.
Genlock
Determines whether the unit will use an external genlock source or its own internal
crystal for timing.
Valid Settings: Auto, Internal
Default Setting: Auto
If the unit is configured to Auto genlock mode, it will use the timing of a connected
stable genlock source, and the Genlock indicator of the unit will be lit. If no genlock
source is present, the unit will automatically switch to using its own internal crystal
for timing, and this indicator will flash.
If the unit is configured to Internal genlock mode, it will operate on its own internal
crystal, and the Genlock indicator will be unlit.
Subcarrier Phase
Adjusts the subcarrier genlock timing, with 0.176° resolution.
Valid Range: 0.000° to 360.000°
Default Setting: 0.000°
Horizontal
Adjusts the horizontal position genlock timing, with 4.630ns resolution.
Valid Range: -4.741 µs to 4.736 µs
Default Setting: 0.000 ns
69

Table of Contents

Related product manuals