5.2011.8583.0 C
7-6 Troubleshooting
Cattle Solution:
Preventive measure:
Cows or bulls have pushed the
bumper.
Resume the route. Ask lely Center to optimise
routes to:
Minimise driving forwards
toward the feed fence
Prevent driving close past
bulls etc
Make sure there is sufficient
clearance between the MFR
and the feed fence or the
cattle
Consider using the optional
electric bumper protection.
High piled up feed Solution:
Preventive measure:
When the feed is piled up, the
tube of the feed height laser can
get caught by feed and activate
the bumper.
Try to spread the feed so the
bumper does not get caught on
it and resume the route.
Consider lowering the dosing
weight for that feed location.
Foreign objects Solution:
Preventive measure:
Farm implements or traffic on an
outside route.
Remove the object and resume
the route
Consider marking the route of
the MFR so it is clear for visitors
where not park vehicles or store
material.
3CCC No initial Feed Flow was detected (<P1>)
No feed falls in the MFR from
the digital output dispenser
Solution:
Preventive measure:
Via a digital output (relay circuit
board on PDB circuit board) a
wide variety of dispensers can
be controlled, ranging from a
water valve to a tower silo and
conveyor belt system. To cater
for all these different
technologies there are settings
to generate an alarm when
problems or blockages are
assumed and to prevent
damage. When no start of a feed
flow has been detected within a
set time (margin) the alarm no
initial feed flow will be
generated. (Info: A start of a
feed flow is recognised by the
MFR if there is 10 kgs increase in
weight or a constant flow of
more than 350g/s for 3 seconds.)
Find the fault why the dispenser
has not started to dose feed in
the MFR, check:
If the system is powered
If the storage is empty
If there is a blockage of
augers, loaders or transport
system
Fix the fault and resume the
feeding task on the MFR.