Troubleshooting 7-7
The dispenser has not started
dumping feed in the MFR before
the set start up margin
Solution:
Preventive measure:
The settings Startup delay and
Startup margin must both be
set correctly, for filled and near
empty dispensers.
Resume feeding task on MFR,
but if no changes are made to
the settings the alarm will occur
again.
Ask your Lely Center to make
adjustments in the settings., if
the alarm was triggered while
the dispenser was operating
normally. The delay setting may
be set too short. Measure the
time the dispenser takes to start
up and use that time as the
setting for delay of that
dispenser. Do not set this time
too long, because the alarm is
there for a reason. When a
conveyor belt or chute is blocked
you do not want to continue
requesting that feed type
endlessly and cause damage or a
pile of feed in the wrong
location.
160D Crane alarm (<P1>)
The Bridge Crane has an alarm,
this alarm is generated on the
Feed Grabber
Solution:
Preventive measure:
The Feed Grabber notifies
messages and alarms of the
Bridge Crane. First the crane
alarm needs to be solved before
the Feed Grabber can be put
back in operation.
Connect the smartphone to the
Bridge Crane and see which
alarm is active, resolve the
problem and put the Bridge
Crane back in operation. Only
then log into the Feed Grabber,
accept the crane alarm and
resume operation of the Feed
Grabber.
If the Bridge Crane alarm is
often caused by slip, you can
prevent this alarm by regularly
cleaning the IPE profiles. Clean
these beams before the season
of fog and condensation starts
(for example during fall and
spring, when cold steel and
warm air can be expected).
In a very dusty kitchen consider
to install the optional brush set.