5.2011.8583.0 C
Troubleshooting 7-23
6. Go to the page Testing > Test Grabber.
7. Use the buttons
OPEN and CLOSE to open or close the grabber.
Open the grabber to a percentage between 120 and 130%.
8. Go to the page Testing > Test Lift Motor.
9. Use the buttons
UP and DOWN to position the grabber.
10. Position the grabber so, that the distance between the teeth and the floor is about 1 m (3.3 ft) (A)
(see figure 68 on page 7-23).
Figure 68. Lower the grabber to the correct distance from the floor
KEY: 1. Safety handle - 2. Chain - 3. Closing belt
A: Distance to the floor
Reinstall the chain
There are two closing belt drums, one in the top (1) (see figure 69 on page 7-24) and one
in the grabber (2). Before each step of the procedure with drums, make sure you know
which drum is involved.
in n o vato rs in agriculture