Step 3. Install the PCIe adapter and secure it to the riser assembly.
Figure 89. PCIe adapter installation into the LP-FH riser assembly
a.
Align the PCIe adapter with the PCIe slot on the riser card. Then, carefully press the PCIe
adapter straight into the slot until it is securely seated and its bracket is secured.
b.
Rotate the latch on the riser bracket to closed position.
Notes:
1. Ensure that PCIe adapter installation meets the rules in
“PCIe slots and adapters” on page 50.
2. The procedure for installing a PCIe adapter is similar for different types of riser assembly. In
this topic, the LP-FH riser assembly is used as an example.
Step 4. Connect cables to the PCIe adapter in the riser assembly. See
Chapter 6 “Internal cable routing” on
page 217
.
After you finish
1. Reinstall the riser assembly. See
“Install a riser card” on page 181.
2. Complete the parts replacement. See
“Complete the parts replacement” on page 215.
Power supply unit air baffle replacement
Use this information to remove and install a power supply unit air baffle (PSU air baffle).
Note: PSU air baffle is installed only when installing a closed loop heat sink (LACM module).
Remove a power supply unit air baffle
Use this information to understand how to remove a power supply unit air baffle.
Chapter 5. Hardware replacement procedures 143