4.  Do a DC power cycle to make the setting take effect. 
Intermittent problems
Use this information to solve intermittent problems.
• 
“Intermittent external device problems” on page 320
•  “Intermittent KVM problems” on page 320
•  “Intermittent unexpected reboots” on page 320
Intermittent external device problems
Complete the following steps until the problem is solved. 
1.  Update the UEFI and XCC firmware to the latest versions.
2.  Make sure that the correct device drivers are installed. See the manufacturer's website for 
documentation.
3.  For a USB device:
a.  Make sure that the device is configured correctly.
Restart the server and press the key according to the on-screen instructions to display the LXPM 
system setup interface. (For more information, see the “Startup” section in the LXPM documentation 
compatible with your server at 
https://sysmgt.lenovofiles.com/help/topic/lxpm_frontend/lxpm_product_ 
page.html
.) Then, click System Settings ➙ Devices and I/O Ports ➙ USB Configuration.
b.  Connect the device to another port. If using a USB hub, remove the hub and connect the device 
directly to the server. Make sure that the device is configured correctly for the port. 
Intermittent KVM problems
Complete the following steps until the problem is solved.
Video problems:
1.  Make sure that all cables and the console breakout cable are properly connected and secure. 
2.  Make sure that the monitor is working properly by testing it on another server.
3.  Test the console breakout cable on a working server to ensure that it is operating properly. Replace the 
console breakout cable if it is defective.
Keyboard problems:
Make sure that all cables and the console breakout cable are properly connected and secure. 
Mouse problems:
Make sure that all cables and the console breakout cable are properly connected and secure. 
Intermittent unexpected reboots
Note:  Some uncorrectable errors require that the server reboot so that it can disable a device, such as a 
memory DIMM or a processor to allow the machine to boot up properly.
1.  If the reset occurs during POST and the POST watchdog timer is enabled, make sure that sufficient time 
is allowed in the watchdog timeout value (POST Watchdog Timer). 
To check the POST watchdog time, restart the server and press the key according to the on-screen 
instructions to display the LXPM system setup interface. (For more information, see the “Startup” 
320
ThinkSystem SR635 V3 User Guide