EasyManua.ls Logo

Lenovo ThinkSystem SR635 V3 - Page 62

Lenovo ThinkSystem SR635 V3
356 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Notes:
For the low-profile + full-height configuration, the PCIe Ethernet adapters listed below cannot be installed
on slot 1.
Lenovo ThinkSystem NetXtreme PCIe 1Gb 4-Port RJ45 Ethernet Adapter By Broadcom
Lenovo ThinkSystem I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter By Intel
ThinkSystem Intel I350-T4 ML2 1Gb 4-Port RJ45 Ethernet Adapter
ThinkSystem Broadcom 57454 10GBASE-T 4-port PCIe Ethernet Adapter
ThinkSystem Broadcom 57504 10/25GbE SFP28 4-port PCIe Ethernet Adapter can only be installed into
the slot with a full-height riser bracket.
Notes: Rules for RAID/HBA adapters:
RAID 940 series adapters require a RAID flash power module.
The RAID 940-8i or RAID 940-16i adapter supports Tri-mode. When Tri-mode is enabled, the server
supports SAS, SATA and U.3 NVMe drives at the same time. NVMe drives are connected via a PCIe x1
link to the controller.
Note: To support Tri-mode with U.3 NVMe drives, U.3 x1 mode must be enabled for the selected drive
slots on the backplane through the XCC Web GUI. Otherwise, the U.3 NVMe drives cannot be detected.
For more information, see
“U.3 NVMe drive can be detected in NVMe connection, but cannot be detected
in Tri-mode” on page 319
.
When Gen 3 M.2 backplane is installed, RAID 5350 or RAID 540 series are not supported.
Technical rules for mixing OCP/PCIe adapters with RAID/HBA adapters
The OCP/PCIe adapters listed in the left column cannot be mixed with the RAID/HBA adapters listed in the
right column.
OCP/PCIe adapters RAID/HBA adapters
ThinkSystem Intel E810-DA4 10/25GbE SFP28 4-port
PCIe Ethernet Adapter
ThinkSystem Intel E810-DA4 10/25GbE SFP28 4-port
OCP Ethernet Adapter
ThinkSystem Intel E810-DA2 10/25GbE SFP28 2-Port
PCIe Ethernet Adapter
ThinkSystem Intel E810-DA2 10/25GbE SFP28 2-Port
OCP Ethernet Adapter
ThinkSystem 4350-8i SAS/SATA 12Gb HBA
ThinkSystem 4350-16i SAS/SATA 12Gb HBA
ThinkSystem RAID 5350-8i PCIe 12Gb Adapter
ThinkSystem RAID 5350-8i PCIe 12Gb Internal Adapter
ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb
Adapter
ThinkSystem RAID 9350-8i 2GB Flash PCIe 12Gb
Internal Adapter
ThinkSystem RAID 9350-16i 4GB Flash PCIe 12Gb
Internal Adapter
Technical rules for mixing PCIe adapters with processors
When processors 9254, 9334, 9224 or 9124 are selected, Broadcom 5719 1GbE RJ45 4-port OCP
Ethernet Adapter or Broadcom 5719 1GbE RJ45 4-port PCIE Ethernet Adapter cannot be installed.
When a Group E processor (320 W cTDP 400 W) is installed, the following 100G PCIe adapters cannot
be selected in the configurations listed in the left column below.
52
ThinkSystem SR635 V3 User Guide

Table of Contents

Other manuals for Lenovo ThinkSystem SR635 V3

Related product manuals