b. Rotate the backplane to vertical position to ensure that the four hooks on the chassis pass
through the corresponding holes in the backplane. Then, slide the new backplane as shown
until it is secured into place.
Step 3. If you have disconnected cables from the backplane, reconnect cables back to the backplane, and
then connect the cables to the system board assembly or RAID adapters. See
Chapter 6 “Internal
cable routing” on page 271
.
After you finish
1. Reinstall all the drives and fillers (if any) into the drive bays. See “Install a hot-swap drive” on page 83.
2. Reinstall the fan cage. See
“Install the system fan cage” on page 260.
3. Reinstall the air baffle if you have removed it. See
“Install the air baffle” on page 87.
4. Complete the parts replacement. See
“Complete the parts replacement” on page 269.
Front I/O module replacement
Use this information to remove and install the front I/O module.
The front I/O module varies by model. The front I/O module for most models is on right rack latch. The front I/
O module on media bay is supported only in the following server models:
• Server models with eight 2.5-inch front drive bays
• Server models with sixteen 2.5-inch front drive bays
Figure 57. Front I/O module (on rack latch) Figure 58. Front I/O module (on media bay)
To replace the front I/O module on the rack latch, see
“Rack latches replacement” on page 192.
To replace the front I/O module on the media bay:
•
“Remove the front I/O module” on page 104
• “Install the front I/O module” on page 106
Chapter 5. Hardware replacement procedures 103