•  Go to https://datacentersupport.lenovo.com/products/servers/thinksystem/sr650v3/7d75/downloads/driver- 
list/
to see the latest firmware and driver updates for your server.
•  Go to 
“Update the firmware” on page 445 for more information on firmware updating tools.
Watch the procedure 
A video of this procedure is available at YouTube: 
https://www.youtube.com/playlist?list=PLYV5R7hVcs- 
BmyijyY0-lNvapM4fTV5Gf
.
Procedure
Step 1.  Install the Torx T30 nut. 
Figure 80. Installing a Torx T30 nut into the heat sink
Note: Do not touch the gold contacts on the bottom of the processor.
a. 
Rotate the anti-tilt wire bail inwards.
b. 
Orient the Torx T30 nut under the anti-tilt wire bail; then, align the Torx T30 nut with the 
socket at an angle as shown.
c.  Push the lower edge of the Torx T30 nut into the socket until it clicks into place. Make sure 
the Torx T30 nut is secured under the four clips in the socket.
After you finish
1.  Reinstall the PHM. See “Install a processor and heat sink” on page 183.
2.  Complete the parts replacement. See 
“Complete the parts replacement” on page 269.
Internal RAID/HBA/expander adapter replacement
Use this information to remove and install an internal customer form factor (CFF) RAID adapter, internal CFF 
HBA adapter, or internal CFF RAID expander adapter.
Chapter 5. Hardware replacement procedures 119