EasyManua.ls Logo

Lenovo ThinkSystem SR650 V3 7D75 - Remove the Middle Drive Cage and Drive; Backplanes

Lenovo ThinkSystem SR650 V3 7D75
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
“Install the middle drive backplanes and drive cage” on page 146
Remove the middle drive cage and drive backplanes
Use this information to remove the middle drive cage and drive backplanes.
About this task
Attention:
Read
“Installation Guidelines” on page 55 and “Safety inspection checklist” on page 56 to ensure that you
work safely.
Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 73.
Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
Before you remove or make changes to drives, drive controllers (including controllers that are integrated
on the system board assembly), drive backplanes or drive cables, back up all important data that is stored
on drives.
Before you remove any component of a RAID array (drive, RAID card, etc.), back up all RAID configuration
information.
If one or more NVMe solid-state drives are to be removed, it is recommended to disable them beforehand
via the operating system.
Watch the procedure
A video of this procedure is available at YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
BmyijyY0-lNvapM4fTV5Gf
.
Procedure
Step 1. Make preparation for the task.
a. If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the
top cover, or remove the server from the rack. See
“Remove the server from rack” on page 73.
b. Remove the top cover. See
“Remove the top cover” on page 266.
c. Remove the system fan cage for easier operation. See
“Remove the system fan cage” on page
259
.
d. Disconnect cables from the middle drive backplanes.
Step 2. Remove the middle drive cage.
Note: The illustration shows removing the 2.5-inch middle drive cage. The procedure is the same
for removing the 3.5-inch middle drive cage.
144
ThinkSystem SR650 V3 User Guide