EasyManua.ls Logo

Lenovo ThinkSystem SR650 V3 7D75 - Drive Cage

Lenovo ThinkSystem SR650 V3 7D75
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
b. Move the rear drive cage forward until it clicks into position.
Step 5. Connect cables from the drive backplanes to the system board or RAID/HBA adapters. See
Chapter 6 “Internal cable routing” on page 271.
After you finish
1. Reinstall the drives or drive fillers into the rear drive cage. See
“Install a hot-swap drive” on page 83.
2. Complete the parts replacement. See
“Complete the parts replacement” on page 269.
Remove the 8 x 2.5" drive backplane and drive cage
Use this information to remove the rear 2.5-inch 8-bay drive backplane and drive cage.
About this task
Attention:
Read
“Installation Guidelines” on page 55 and “Safety inspection checklist” on page 56 to ensure that you
work safely.
Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 73.
Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
Before you remove or make changes to drives, drive controllers (including controllers that are integrated
on the system board assembly), drive backplanes or drive cables, back up all important data that is stored
on drives.
Before you remove any component of a RAID array (drive, RAID card, etc.), back up all RAID configuration
information.
If one or more NVMe solid-state drives are to be removed, it is recommended to disable them beforehand
via the operating system.
Watch the procedure
A video of this procedure is available at YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
BmyijyY0-lNvapM4fTV5Gf
.
Procedure
Step 1. Make preparation for the task.
a. If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the
top cover, or remove the server from the rack. See
“Remove the server from rack” on page 73.
b. Remove the top cover. See
“Remove the top cover” on page 266.
c. Disconnect cables from the rear drive backplane.
d. Remove all the installed drives and fillers (if any) from the drive bays. See
“Remove a hot-swap
drive” on page 82
.
Step 2. Remove the rear drive cage.
Chapter 5. Hardware replacement procedures 225

Table of Contents

Related product manuals