Procedure
Step 1. Touch the static-protective package that contains the new part to any unpainted surface on the
outside of the server. Then, take the new part out of the package and place it on a static-protective
surface.
Step 2. Connect cables to the drive backplane. See
Chapter 6 “Internal cable routing” on page 271.
Step 3. Install the drive backplane into the rear drive cage.
Figure 195. Installing the 4 x 2.5-inch rear drive backplane
a. Align the bottom of the backplane with the studs at the bottom of the drive cage.
b. Lower the backplane into the drive cage so that the holes in the backplane pass through the
pins on the drive cage, and press the backplane into position. The release latches will secure
the backplane in place.
Step 4. Install the rear drive cage.
Figure 196. Installing the 4 x 2.5-inch rear drive cage
a. Align the rear drive cage with the chassis, and lower the drive cage into the chassis.
224
ThinkSystem SR650 V3 User Guide