Procedure
Step 1. Make preparation for the task.
a. If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the
top cover, or remove the server from the rack. See
“Remove the server from rack” on page 73.
b. Remove the top cover. See
“Remove the top cover” on page 266.
c. Remove the fan cage from the system board assembly. See
“Remove the system fan cage” on
page 259
.
d. Remove the system fans from the fan cage. See
“Remove a system fan” on page 255.
Step 2. Remove the intrusion switch assembly from the fan cage.
Note: The blowup in the illustration shows the fan cage upside down.
Figure 84. Intrusion switch removal
a. Move the intrusion switch connector in the direction as shown to disengage it from the
keyhole.
b.
Release the intrusion switch cable from the pre-cut slots on the foam and fan cage bottom.
c.
Release the intrusion switch cable from the cable clip.
d.
Slide and pull the intrusion switch to remove it from the holder.
After you finish
1. Install a new intrusion switch. See “Install the intrusion switch” on page 124.
2. If you are instructed to return the component or optional device, follow all packaging instructions, and
use any packaging materials for shipping that are supplied to you.
Install the intrusion switch
Use this information to install the intrusion switch.