Lenovo ThinkSystem SR650 V3 7D75 - Heat Sink Torx T30 Nut Replacement; Remove a Heat Sink Torx T30 Nut

Lenovo ThinkSystem SR650 V3 7D75
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
After you finish
Complete the parts replacement. See “Complete the parts replacement” on page 269.
Heat sink Torx T30 nut replacement
Use this information to remove and install a heat sink Torx T30 nut.
Remove a heat sink Torx T30 nut
This task has instructions for removing a PEEK (Polyether ether ketone) Torx T30 nut on the heat sink.
About this task
Attention:
Read
“Installation Guidelines” on page 55 and “Safety inspection checklist” on page 56 to ensure that you
work safely.
Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 73.
Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
Do not touch the processor contacts. Contaminants on the processor contacts, such as oil from your skin,
can cause connection failures.
Note: The heat sink, processor, and processor carrier for your system might be different from those shown
in the illustrations.
Watch the procedure
A video of this procedure is available at YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
BmyijyY0-lNvapM4fTV5Gf
.
Procedure
Step 1. Make preparation for the task.
a. If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the
top cover, or remove the server from the rack. See
“Remove the server from rack” on page 73.
b. Remove the top cover. See
“Remove the top cover” on page 266.
c. If your server comes with an air baffle or a middle cage, remove it first.
“Remove the air baffle” on page 85
“Remove the middle drive cage and drive backplanes” on page 144
d. Remove the system fan cage if needed. “Remove the system fan cage” on page 259.
e. Remove the PHM. See
“Remove a processor and heat sink” on page 176.
Step 2. Remove the Torx T30 nut.
Chapter 5. Hardware replacement procedures 117