Figure 139. PHM components
1 Heat sink
9 Clips to secure processor in carrier
2 Heat sink triangular mark
10 Carrier triangular mark
3 Processor identification label
11 Processor ejector handle
4 Nut and wire bail retainer 12 Processor heat spreader
5 Torx T30 nut 13 Thermal grease
6 Anti-tilt wire bail 14 Processor contacts
7 Processor carrier 15 Processor triangular mark
8 Clips to secure carrier to heat sink
Watch the procedure
A video of this procedure is available at YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
BmyijyY0-lNvapM4fTV5Gf
.
Procedure
Step 1. Make preparations for this task.
a. If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the
top cover, or remove the server from the rack. See “Remove the server from rack” on page 73.
b. Remove the top cover. See “Remove the top cover” on page 266.