Address Designaon Default seng Category Data type Factor A M
0x2863
(P705.00)
Keypad language selecon English [1] general U8 1 P -
0x2864
(P703.00)
Keypad status display 0x00000000 general IDX 1 PH -
0x2900:001
(P332.01)
Speed controller sengs: Gain 0.00193 Nm/rpm * MCTRL U32 100000 P -
0x2900:002
(P332.02)
Speed controller sengs: Reset me 80.0 ms * MCTRL U16 10 P -
0x2901 Speed controller gain adapon 100.00 % MCTRL U16 100 OP r
0x2904 Actual speed lter me 2.0 ms MCTRL U16 10 P -
0x2910:001
(P335.01)
Motor moment of inera 3.70 kg cm² * MCTRL U32 100 P -
0x2910:002
(P335.02)
Load moment of inera 3.70 kg cm² * MCTRL U32 100 P -
0x2910:003 Coupling With backlash [2] MCTRL U8 1 P -
0x2911:001
(P450.01)
Frequency setpoint presets: Preset 1 20.0 Hz general U16 10 P -
0x2911:002
(P450.02)
Frequency setpoint presets: Preset 2 40.0 Hz general U16 10 P -
0x2911:003
(P450.03)
Frequency setpoint presets: Preset 3 Device for 50-Hz mains:
50.0 Hz
Device for 60-Hz mains:
60.0 Hz
general U16 10 P -
0x2911:004
(P450.04)
Frequency setpoint presets: Preset 4 0.0 Hz general U16 10 P -
0x2911:005
(P450.05)
Frequency setpoint presets: Preset 5 0.0 Hz general U16 10 P -
0x2911:006
(P450.06)
Frequency setpoint presets: Preset 6 0.0 Hz general U16 10 P -
0x2911:007
(P450.07)
Frequency setpoint presets: Preset 7 0.0 Hz general U16 10 P -
0x2911:008
(P450.08)
Frequency setpoint presets: Preset 8 0.0 Hz general U16 10 P -
0x2911:009
(P450.09)
Frequency setpoint presets: Preset 9 0.0 Hz general U16 10 P -
0x2911:010
(P450.10)
Frequency setpoint presets: Preset 10 0.0 Hz general U16 10 P -
0x2911:011
(P450.11)
Frequency setpoint presets: Preset 11 0.0 Hz general U16 10 P -
0x2911:012
(P450.12)
Frequency setpoint presets: Preset 12 0.0 Hz general U16 10 P -
0x2911:013
(P450.13)
Frequency setpoint presets: Preset 13 0.0 Hz general U16 10 P -
0x2911:014
(P450.14)
Frequency setpoint presets: Preset 14 0.0 Hz general U16 10 P -
0x2911:015
(P450.15)
Frequency setpoint presets: Preset 15 0.0 Hz general U16 10 P -
0x2912:001
(P452.01)
Torque setpoint presets: Preset 1 100.0 % general I16 10 P -
0x2912:002
(P452.02)
Torque setpoint presets: Preset 2 100.0 % general I16 10 P -
0x2912:003
(P452.03)
Torque setpoint presets: Preset 3 100.0 % general I16 10 P -
0x2912:004
(P452.04)
Torque setpoint presets: Preset 4 100.0 % general I16 10 P -
0x2912:005
(P452.05)
Torque setpoint presets: Preset 5 100.0 % general I16 10 P -
0x2912:006
(P452.06)
Torque setpoint presets: Preset 6 100.0 % general I16 10 P -
* Default seng depending on the size. Firmware version 05.00.00.00
Appendix
Parameter aribute list
686