EasyManua.ls Logo

Lenze i55AE155F

Lenze i55AE155F
702 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Name / value range / [default seng] Info
0x4018:006 Relay: Trigger signal state
Read only
Display of the logic state of the trigger signal for the relay (without tak-
ing a ON/OFF delay set and inversion into consideraon).
0 FALSE
1 TRUE
0x4018:007 Relay: Switching cycles
Read only
Display of the previous relay switching cycles.
14.15.2 Digital output 1
Sengs for digital output 1.
Details
The digital output 1 is controlled with the trigger selected in 0x2634:002 (P420.02).
The following sengs are possible for the digital output:
Inversion
Switch-on delay
Cutout delay
DO1
0x4016:0050x4016:006
1
0
1
0x2635 002: 0x4016 004: 0x4016:003
0x2634:002
X3
Trigger
Diagnosc parameters:
The logic status of the trigger signal is displayed in 0x4016:006.
The logic status of the digital output is displayed in 0x4016:005.
Parameter Name / value range / [default seng] Info
0x2634:002
(P420.02)
Digital outputs funcon: Digital output 1
(Dig.out.funcon: DO1 funcon)
For further possible sengs, see parameter
0x2634:001 (P420.01). ^ 603
Assignment of a trigger to digital output 1.
Trigger = FALSE: X3/DO1 set to LOW level.
Trigger = TRUE: X3/DO1 set to HIGH level.
Notes:
An inversion set in 0x2635:002 (P421.02) is taken into consideraon
here.
115 Release holding brake
100 Sequencer controlled (from version 03.00) The control is executed via the sequencer (according to the congura-
on of the digital outputs for the current segment).
4Segment conguraon ^ 506
0x2635:002
(P421.02)
Inversion of digital outputs: Digital output 1
(DO inversion: DO1 inversion)
Inversion of digital output 1
0 Not inverted
1 Inverted
0x4016:003 Digital output 1: Cutout delay
0.000 ... [0.000] ... 65.535 s
Switch-o delay for digital output 1.
Note!
The set delay me is not eecve (internally set to "0") if the relay is
assigned to the trigger "Release holding brake [115]". Only the decelera-
on me set in 0x2820:012 (P712.12)for closing the holding brake inu-
ences the me-dependent behaviour of the digital output.
0x4016:004 Digital output 1: Switch-on delay
0.000 ... [0.000] ... 65.535 s
Switch-on delay for digital output 1.
Note!
The set delay me is not eecve (internally set to "0") if the relay is
assigned to the trigger "Release holding brake [115]". Only the decelera-
on me set in 0x2820:012 (P712.12)for closing the holding brake inu-
ences the me-dependent behaviour of the digital output.
0x4016:005 Digital output 1: Terminal state
Read only
Display of the logic state of output terminal X3/DO1.
0 FALSE
1 TRUE
0x4016:006 Digital output 1: Trigger signal state
Read only
Display of the logic state of the trigger signal for digital output 1 (without
taking a ON/OFF delay set and inversion into consideraon).
0 FALSE
1 TRUE
Flexible I/O conguraon
Conguraon of digital outputs
Digital output 1
607