6.2.4.4 EtherNet/IP diagnoscs
The following parameters serve to diagnose the EtherNet/IP interface and the communicaon
via EtherNet/IP.
Precondions
Control unit (CU) of the inverter is provided with EtherNet/IP.
Parameter Name / value range / [default seng] Info
0x23A2:001
(P511.01)
Acve EtherNet/IP sengs: IP address
(EtherN/IP diag.: IP address)
•
Read only
•
From version 02.00
Display of the acve IP address.
The default seng 276605120 corresponds to the IP address
192.168.124.16.
•
276605120 = 0x107CA8C0 à 0xC0.0xA8.0x7C.0x10 = 192.168.124.16
0x23A2:002
(P511.02)
Acve EtherNet/IP sengs: Subnet
(EtherN/IP diag.: Subnet)
•
Read only
•
From version 02.00
Display of the acve subnet mask.
The default seng 16777215 corresponds to the subnet mask
255.255.255.0.
•
16777215 = 0xFFFFFF à 0xFF.0xFF.0xFF.0x00 = 255.255.255.0
0x23A2:003
(P511.03)
Acve EtherNet/IP sengs: Gateway
(EtherN/IP diag.: Gateway)
•
Read only
•
From version 02.00
Display of the acve gateway address.
Example:
The seng 276344004 corresponds to the gateway address
196.172.120.16.
•
276344004 = 0x1078ACC4 à 0xC4.0xAC.0x78.0x10 = 196.172.120.16
0x23A2:005
(P511.05)
Acve EtherNet/IP sengs: MAC address
(EtherN/IP diag.: MAC address)
•
Read only
•
From version 02.00
Display of the acve MAC address.
0x23A2:006
(P511.06)
Acve EtherNet/IP sengs: Mulcast address
(EtherN/IP diag.: Mcast address)
•
Read only
•
From version 02.00
Display of the acve Mulcast IP address.
The default seng 3221373167 corresponds to the Mulcast IP address
239.64.2.192.
•
3221373167 = 0xC00240EF à 0xEF.0x40.0x02.0xC0 = 239.64.2.192
0x23A3
(P509.00)
EtherNet/IP switch posion
(EtherN. switch)
•
Read only
•
From version 02.00
Display of the rotary encoder switch sengs at the last mains power-on.
0x23A5:001
(P519.01)
Acve port sengs: Port 1
(Port diagnoscs: Port 1)
•
Read only
•
From version 02.00
Display of the acve baud rate for Ethernet port 1.
0 Not connected
1 10 Mbps/Half Duplex
2 10 Mbps/Full Duplex
3 100 Mbps/Half Duplex
4 100 Mbps/Full Duplex
0x23A5:002
(P519.02)
Acve port sengs: Port 2
(Port diagnoscs: Port 2)
•
Read only
•
From version 02.00
Display of the acve baud rate for Ethernet port 2.
0 Not connected
1 10 Mbps/Half Duplex
2 10 Mbps/Full Duplex
3 100 Mbps/Half Duplex
4 100 Mbps/Full Duplex
5 Reserved
6 Reserved
0x23A6
(P513.00)
Quality of service
(QualityOfService)
•
Read only
•
From version 02.00
Display if the QoS tag for priorising the data packages to be transmied
is used.
0 802.1Q Tag disable
1 802.1Q Tag enable
0x23A8
(P516.00)
CIP module status
(CIP module stat.)
•
Read only
•
From version 02.00
Display of the acve CIP module status.
Diagnoscs and fault eliminaon
Diagnoscs parameter
Network diagnoscs
125