Parameter Name / value range / [default seng] Info
0x2550:011
(P707.11)
Brake resistor: Response to error
(Brake resistor: Error response)
•
For further possible sengs, see parameter
0x2D45:001 (P310.01). ^ 223
Selecon of the response to be executed when the error threshold for
brake resistor monitoring is reached.
Associated error code:
•
65282 | 0xFF02 - Brake resistor: overload warning
3 Fault
11.5.2 Stopping the deceleraon ramp funcon generator
The deceleraon ramp funcon generator is stopped for a short me if the voltage threshold
for braking operaon is exceeded.
Details
When this braking method is selected, the maximum permissible me for the deceleraon
override has to be set in 0x2541:005 (P706.05).
•
If the DC-bus voltage does not fall below the voltage threshold for braking operaon
shown in 0x2541:002 (P706.02) within this me, the motor is decelerated further.
•
The me is only reset if the voltage threshold shown in 0x2541:002 (P706.02) is not
reached.
Addional funcons
Brake energy management
Stopping the deceleraon ramp funcon generator
447