Address Designaon Default seng Category Data type Factor A M
0x2859:001
(P515.01)
EtherNet/IP monitoring: Watchdog elapsed Trouble [2] EtherNet/IP U8 1 P -
0x2859:001
(P515.01)
PROFINET monitoring: Watchdog elapsed Trouble [2] PROFINET U8 1 P -
0x2859:001
(P515.01)
EtherCAT monitoring: Watchdog elapsed Trouble [2] EtherCAT U8 1 P -
0x2859:001 POWERLINK monitoring: Watchdog elapsed Trouble [2] POWERLINK U8 1 P -
0x2859:002
(P515.02)
PROFIBUS monitoring: Data exchange exited No response [0] PROFIBUS U8 1 P -
0x2859:002
(P515.02)
PROFINET monitoring: Data exchange exited No response [0] PROFINET U8 1 P -
0x2859:003
(P515.03)
PROFIBUS monitoring: Invalid conguraon Trouble [2] PROFIBUS U8 1 P -
0x2859:003
(P515.03)
EtherNet/IP monitoring: Invalid conguraon Trouble [2] EtherNet/IP U8 1 P -
0x2859:003
(P515.03)
Modbus TCP/IP monitoring: Conguraon error Trouble [2] Modbus TCP U8 1 P -
0x2859:003
(P515.03)
PROFINET monitoring: Invalid conguraon Trouble [2] PROFINET U8 1 P -
0x2859:003
(P515.03)
EtherCAT monitoring: Invalid conguraon Trouble [2] EtherCAT U8 1 P -
0x2859:004
(P515.04)
PROFIBUS monitoring: Inialisaon error Trouble [2] PROFIBUS U8 1 P -
0x2859:004
(P515.04)
EtherNet/IP monitoring: Inialisaon error Trouble [2] EtherNet/IP U8 1 P -
0x2859:004
(P515.04)
Modbus TCP/IP monitoring: Inialisaon error Trouble [2] Modbus TCP U8 1 P -
0x2859:004
(P515.04)
PROFINET monitoring: Inialisaon error Trouble [2] PROFINET U8 1 P -
0x2859:004
(P515.04)
EtherCAT monitoring: Inialisaon error Trouble [2] EtherCAT U8 1 P -
0x2859:005
(P515.05)
PROFIBUS monitoring: Invalid process data Trouble [2] PROFIBUS U8 1 P -
0x2859:005
(P515.05)
EtherNet/IP monitoring: Invalid process data Trouble [2] EtherNet/IP U8 1 P -
0x2859:005
(P515.05)
PROFINET monitoring: Invalid process data Trouble [2] PROFINET U8 1 P -
0x2859:005
(P515.05)
EtherCAT monitoring: Invalid process data Trouble [2] EtherCAT U8 1 P -
0x2859:006
(P515.06)
EtherNet/IP monitoring: Timeout explicit message Warning [1] EtherNet/IP U8 1 P -
0x2859:007
(P515.07)
EtherNet/IP monitoring: Timeout communicaon Warning [1] EtherNet/IP U8 1 P -
0x2859:007
(P515.07)
Modbus TCP/IP monitoring: Fault reacon by me-
out Network
Warning [1] Modbus TCP U8 1 P -
0x2859:008
(P515.08)
Modbus TCP/IP monitoring: Fault reacon by me-
out Master
Fault [3] Modbus TCP U8 1 P -
0x2859:009
(P515.09)
Modbus TCP/IP monitoring: Fault reacon by me-
out Keep alive
Fault [3] Modbus TCP U8 1 P -
0x2859:010 POWERLINK monitoring: CRC error Trouble [2] POWERLINK U8 1 P -
0x2859:011 POWERLINK monitoring: Loss of SoC Trouble [2] POWERLINK U8 1 P -
0x2860:001
(P201.01)
Frequency control: Default setpoint source Analog input 1 [2] general U8 1 P -
0x2860:002
(P201.02)
PID control: Default setpoint source Keypad [1] general U8 1 P -
0x2860:003
(P201.03)
Torque control: Default setpoint source Analog input 1 [2] general U8 1 P -
0x2862
(P701.00)
Keypad setpoint increment 1 general U16 1 P -