85 user attendance error messages
Error code Description Action
85.01 The black imaging unit is nearly low. The
photoconductor threshold has been reached.
See
“Cartridge or photoconductor error service
check” on page 159.
85.09 The black imaging unit is nearly low. The
userselected EWS set point has been reached.
85.11 The black imaging unit is low. The
photoconductor threshold has been reached.
85.19 The black imaging unit is low. The userselected
EWS set point has been reached.
85.21 The black imaging unit is very low. The
photoconductor threshold has been reached.
85.29 The black imaging unit is very low. The
userselected EWS set point has been reached.
85.31 Replace the black imaging unit. The black
imaging unit has exceeded its recommended life
span. The photoconductor threshold for “End of
Life” has been reached. The black developer
may continue to function beyond end of life.
85.39 Replace black imaging unit. The black imaging
unit has exceeded its recommended life span.
The userselected EWS set point has been
reached. The black developer may continue to
function beyond end of life.
85.41 Replace black imaging unit to resume printing.
The photoconductor threshold for “Absolute End
of Life” has been reached.
5028
Diagnostic information
154

Table of Contents

Other manuals for Lexmark CS725R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lexmark CS725R and is the answer not in the manual?

Lexmark CS725R Specifications

General IconGeneral
BrandLexmark
ModelCS725R
CategoryPrinter
LanguageEnglish

Related product manuals