Impolite ID Timer:
This timer waits until either the timer expires or activity goes away before sending an ID.
- This timer is programmed in 1Sec increments from 1..9999
- If a timer value of 000 is entered, the controller will not interrupt a conversation to send an ID.
Note: that in this case, the 10 minute ID requirement could be broken.
Timer Number Description Defaults
40 Impolite ID Timer, Port 1 20 sec (20)
41 Impolite ID Timer, Port 2 "
42 Impolite ID Timer, Port 3 "
43 Impolite ID Timer, Port 4 "
Initial ID Timer:
This timer times the amount of inactivity before an initial ID is sent.
- This timer is programmed in 1Sec increments from 1..9999
- If a timer value of 0 is entered, the controller will never send an initial ID.
Timer Number Description Defaults
44 Initial ID Timer, Port 1 10 min (600)
45 Initial ID Timer, Port 2 "
46 Initial ID Timer, Port 3 "
47 Initial ID Timer, Port 4 "